top of page

B watch out with thermal break  

67RT Thermic Plus System

Sistema de batente com rotura térmica de elevadas prestações térmicas e acústicas.

O sistema AJi possibilita a execução de 3 versões de caixilharia:
• Linha reta;
• Linha curva;
• Linha oval.

O sistema AJi permite a aplicação de vidros duplos ou triplos de alto rendimento de modo a responder às exigências de isolamento térmico e acústico.

Com um óptimo isolamento térmico aliado à aplicação de um inovador produto designado por baguete ThermoProfile, o Sistema AJi proporciona elevadas prestações de conforto e de economia energética.

Characteristics

Rapture of thermal bridge

European camera stop system

Alloy extrusion profiles 6063

Overall thickness 1.5 mm

Assembly of glass by pressure bites or with springs

Central sale in EPDM with vulcanized corners

Common stops and stop joints in stop systems

Aluminum connection brackets

Steel, stainless and zamak alignment brackets

Hidden mobile rim drainage

Fixed rim depth 67/73 mm

Mobile ring depth 74 mm

Possibility of combining straight and curved rims, sheets and bites

Solid mechanical connection made of high-strength polyamide

AJI 2.jpg

67RT Thermic Plus SYSTEM

Two-leaf swing-window with dimensions ≤ 2.7m²

Glazed 6/16/6 BE

• The aluminum profiles are extruded in 6060 aluminum alloy for architecture according to NP EN 12020-02.


• Thermal break obtained by inserting 24 mm omega-type polyamide insulating rods reinforced with 25% fiberglass.


• Average thickness of aluminum profiles of 1.7 mm.

to fixed ros

• 70 mm fixed rim section with triple chamber;


• Profiles with thermal break with 24 mm omega-type polyamide rods;


• Fixed rims with double quick-clamping square and alignment squares for miter mounting;


• Double-jointed crossbars for a more effective grip;


• Traditional fixed hoops for the domestic market;


• Fixed hoops with external clip and 25 mm or 45 mm direct finishing flap for the French market;


• Fixed rim with exterior and interior clip for application of 30, 50 or 80 mm finishing for the French market;


• Fixed ring for connection to the sliding system with CW thermal break.

to mobile roses

• 78 mm mobile rim section with triple chamber;


• Mobile rings with thermal break through 24 mm omega-type polyamide rods;


• Movable rims with double quick-clamping square and alignment squares for miter mounting;


• Inverter profile with eye for better application of the inverter top.

D sizing and maneuverability

• Minimum dimensions - maximum sheet dimensions: 340 mm - 1700 mm (L); 340 mm - 3000 mm (H);


• Maximum weight for windows or balcony doors up to 170 kg;


• Maximum weight for entrance doors up to 160 kg/leaf;


• Opening possibilities: fixed, interior stop 1 or 2 leaves with or without tilt-stop, exterior stop, tilt, projection, harmonium and parallel-swivel;


• Profile solution for pedestrian or balcony doors with interior or exterior opening according to the PMR standard (people with reduced mobility);


• Filling for double or triple glazing from 20 mm to 55 mm;


• Watertightness ensured through double EPDM gaskets (interior and central).

performances


• Laboratory certified system notified for Initial Type Tests (ITT) according to product standard EN 14351-1 for CE Marking purposes.

performances _

Categories achieved in the evaluation of the window typology AJi system:


• Air permeability: Class 4 (EN 1026 test standard)


• Water tightness: Class E900 (test standard EN 1027)


• Wind resistance: Class C5 (test standard EN 12211)

Categories achieved in the evaluation of the AJi system balcony door typology:


• Air permeability: Class 4 (EN 1026 test standard)


• Water tightness: Class E900 (test standard EN 1027)


• Wind resistance: Class C4 (test standard EN 12211)

Categories achieved in the evaluation of the AJi system gateway typology:


• Air permeability: Class 4 (EN 1026 test standard)


• Water tightness: Class 7A (test standard EN 1027)


• Wind resistance: Class C4 (test standard EN 12211)

Thermal transmission coefficient of 2-ply span with 1.20 mx 1.50 m with glass Ug = 0.5 W/m2K with interlayer "Warm Edge" effect:
• Uw = 1.26 W/m2K

Acoustic attenuation coefficient of 2-leaf span:
• Rw (C ; Ctr) = 42 dB (-1, -4)

Application areas according to RCCTE (depending on the Ug value): I1, I2, I3, V1, V2, V3

bottom of page