• The aluminum profiles are extruded in 6060 aluminum alloy for architecture according to NP EN 12020-02.


• Average thickness of 1.5 mm aluminum profiles for windows and doors.

to fixed ros

• Section of fixed rims of 40 mm or 72 mm;


• Fixed rims with square for mounting in miter.

The mobile roses

• 48 mm mobile frame section;


• Filling for single or double glass from 4 mm to 32 mm;


• Straight, curved, non-bite tradition or non-bite oval rims;


• Straight line or tradition inverter profile.

D sizing and maneuverability

Sizing and maneuverability


• Minimum dimensions - maximum sheet dimensions: 375 mm - 1700 mm (L); 410 mm - 2700 mm (H);


• Maximum weight of 110 kg per leaf with swing-stop;


• Maximum weight of 90 kg per leaf for opening windows;


• Maximum weight of 150 kg per leaf with door hinge;


• Opening possibilities: interior stop (with or without oscillating-stop), exterior, tilting, projecting, pivoting, harmonium and oscill-parallel;


• Watertightness ensured through triple EPDM gaskets.

performances _

• Laboratory certified system notified for Initial Type Tests (ITT) according to product standard EN 14351-1 for CE Marking purposes.

Categories achieved in the evaluation of the AZ window typology system:


• Air permeability: Class 4 (EN 1026 test standard)


• Water tightness: Class 9A (test standard EN 1027)


• Wind resistance: Class C5 (test standard EN 12211)

Categories achieved in the evaluation of the door typology AZ system:


• Air permeability: Class 3 (test standard EN 1026)


• Water tightness: Class 8A (test standard EN 1027)


• Wind resistance: Class C2 (test standard EN 12211)


• Resistance to static torsion: Apto 350N (test standard EN 14609)

Thermal transmission coefficient of 2-ply span with 1.20 mx 1.50 m with glass Ug = 1.4 W/m2K:
• Uw = 2.92 (W/m2.K)

Acoustic attenuation coefficient of 2-leaf span with 4/12/4 glass:
• Rw (C; Ctr) = 33 dB (-1; -4)

Application areas according to RCCTE (depending on the Ug value): I1, I2, I3, V1, V2, V3;